
A stearic acid coating turns ground calcium carbonate from a hydrophilic mineral into an organophilic filler. What the treatment changes in the compound, how coating level is verified, and which lines belong in the purchase specification.
Ground calcium carbonate is hydrophilic by nature: its surface carries polar carbonate sites that water wets readily and that most polymers do not. A stearic acid coating is the industry's standard answer — a thin fatty-acid layer that turns the particle surface organophilic without changing the mineral underneath. Buyers meet it on quotations and certificates as "coated", "surface-treated" or "activated", and at the same mesh the gap between a coated and an uncoated grade is often wider than the gap between two neighbouring mesh grades. This guide covers what the coating is, what it changes in a compound, how it is verified, and which lines belong in a purchase specification.
What "stearic acid coated" means on a spec sheet
The treatment is applied after grinding, in a heated high-shear mixer. The powder is brought up to temperature, the fatty acid is added, and the batch is held while the acid spreads across the particle surfaces. Stearic acid is a saturated C18 fatty acid: its carboxyl head has an affinity for the calcium sites of a carbonate surface, while its long hydrocarbon tail points outward. The particle that results behaves less like a mineral and more like an organic filler.
Three words on a quotation usually mean the same family of treatment, but they are not strict synonyms, and it is worth asking which one is meant rather than assuming: coated and surface-treated are generic, activated usually signals a fatty-acid treatment specifically, and stearate points to the stearic acid family rather than to a silane or a titanate coupling agent. If your process depends on the difference, put the chemical type in writing.
Why stearic acid rather than another treatment
Surface treatment exists to fix one specific problem: the mismatch between a polar mineral surface and a non-polar matrix. Stearic acid is the workhorse because it addresses that mismatch directly and cheaply.
- It works on the interface that actually fails. The hydrocarbon tail is compatible with polyethylene, polypropylene, PVC plasticiser systems and most rubbers, so the particle is wetted by the matrix instead of being pushed out of it.
- It is a commodity chemical with a known safety profile. Stearic acid is a standard food and pharmaceutical excipient, which keeps documentation straightforward in applications where the filler touches consumer goods.
- It needs no exotic equipment. A heated high-shear mixer is enough, which is why the treatment can be offered as a routine production option rather than a special project.
Coupling agents — silanes, titanates, zirconates — do a different job: they build a chemical bridge to a particular resin chemistry and carry a very different cost. They earn their place in engineering compounds and some high-performance coatings. For commodity filling in PVC, PE, PP, rubber and masterbatch, the fatty-acid route is the mainstream one, and it is the treatment a mineral supplier is most likely to run routinely. For the polymer-side view of where GCC fits, see our notes on plastics and rubber and plastics additives.
What the coating changes in the compound
Bulk density, flow and feeding
A coated powder is not simply the same powder with a different label. The fatty-acid layer reduces particle-particle friction, so the material flows more freely — but it also tends to sit at a lower bulk density than the uncoated grade of the same fineness, because the coating interferes with close packing. Both effects reach your plant as practical consequences: silo capacity, screw-feeder calibration, bag fill weight and container loading all shift when you switch. Treat the change as a change of bulk material, not just of surface chemistry, and re-check feeder settings before the first production run.
Dispersion and viscosity
In a non-polar matrix the coated particle wets out faster and breaks down into primary particles with less mechanical work. That is what makes high filler loadings practical: the compound reaches its viscosity or torque limit later, so more mineral can be added before the line complains. How much later depends on the resin, the grade and the mixing equipment, and it is one of the few things a supplier cannot predict for you — a trial on your own line settles it in an afternoon.
Moisture pickup and storage
Because the surface no longer welcomes water, a coated grade picks up less moisture from humid air and stays free-flowing in the bag for longer. It is a real benefit in tropical warehouses and on long sea freight. It is not a moisture barrier: the coating slows uptake, it does not stop it, so the bags still need a dry store and pallets still need to stay off a damp floor.
How coating level and activation are checked
Two separate questions hide behind the word "coated": how much acid is on the powder, and how completely it covers the surface. A certificate can only answer the first one well; the second is better judged by behaviour.
The float test as a shop-floor check
Dust a little powder onto the surface of water in a glass. A well-coated carbonate tends to sit on the surface and resist wetting; an uncoated one wets and sinks, sometimes visibly releasing bubbles as water displaces air. The test is coarse, but it is fast, needs no laboratory, and is genuinely useful for one job: comparing an incoming delivery against the retained sample you approved. It tells you whether the treatment is present and roughly how complete it is — it does not tell you the percentage.
Coating content: what the number does and does not tell you
Coating content is normally reported as a percentage of powder weight, obtained either by extracting the organic fraction or by loss on ignition, depending on the method the two sides agree. The complication is that no single percentage is "correct": a fine grade has far more surface area per gramme than a coarse one and needs more acid to reach the same coverage. A 1250 mesh grade and a 400 mesh grade carrying the same quoted percentage are not coated to the same degree. That is why the figure has to travel with the base grade and the test method — a bare percentage in a quotation is close to meaningless on its own. Our mesh size guide explains how the nominal grade maps to a measured distribution.
The specification lines that matter for a coated grade
A coated grade needs everything an uncoated one needs, plus the treatment defined. In practice the list looks like this:
- Base grade — nominal mesh plus a top cut or D97 figure. The coating does not remove oversize particles, so the size distribution still has to be specified.
- Coating type and level — stearic acid (or another named chemistry) and a percentage range, with the test method for that percentage.
- Residual moisture — our GCC grades are specified at ≤0.3%, which is what keeps a coated powder free-flowing in the bag.
- Whiteness and carbonate content — our line runs 85–96% whiteness and 88–98% CaCO₃, set by the calcite ore. The coating itself does not whiten the powder, so these lines describe the mineral, not the treatment.
- Sieve residue — grits survive coating just as they survive grinding, and in thin films or fine mouldings they are the defect you notice first.
- Bulk or apparent density — worth writing down if feeding or silo capacity is tight, because coated and uncoated are not interchangeable at the same setting.
Where a coated grade is the wrong choice
The treatment is not a universal upgrade. It is the wrong purchase when the process is water-borne: a hydrophobic surface actively fights wetting in an aqueous system, so a coated filler can need more dispersant, disperse more slowly and leave defects that an uncoated grade would not. This is why water-based paint formulators usually stay with uncoated powder — our article on GCC for water-based paint covers that case in detail. The same logic applies wherever the mineral's job depends on a hydrophilic surface or on reacting with an aqueous phase.
There is a second, quieter failure mode: over-treatment. More acid than the surface can hold leaves free fatty acid in the powder, which can show up as odour in the bag, as deposit on a mould, or as poor adhesion between layers in a multi-layer film. If a coated grade suddenly behaves worse than the sample you approved, ask about coating level before blaming the resin.
Sourcing coated GCC from China: what to settle before the PO
TDHX Minerals grinds GCC from Liaoning calcite in grades from 800 mesh through 1250 mesh to 3000 mesh, with the full ladder listed on the heavy calcium carbonate powder page, and supplies each grade coated or uncoated. Whiteness runs 85–96% and CaCO₃ 88–98%, moisture ≤0.3%. Material ships in 25/50 kg bags or 1000/1250 kg jumbo bags; a 20-foot container carries roughly 25–27 tonnes through Dalian or Yingkou with a 7–15 day lead time.
Because coating is a production step rather than a catalogue item, four things are worth settling before the order: the coating level per grade, in writing and with its method; whether the certificate of analysis reports values on a coated or uncoated basis, since the organic fraction shifts loss on ignition and titration figures; a retained sample per batch, so the float test in your goods-in area has a reference; and the free-acid limit if odour or mould deposit matters in your process. Send us your base mesh, target coating level and resin system, and we reply with a quotation and a 0.5–1 kg sample within 24 hours. If you are still deciding what the mineral can do at all, start with our introduction to ground calcium carbonate or the GCC versus PCC comparison.


